Experimental investigation of flow rates through composites liners at the metric scale
Investigation des débits de fuite dans les étanchéités composites à l'échelle métrique
Résumé
The hydraulic behaviour of 17 composite liners was investigated at the metric scale in the laboratory using 1m diameter cells. A 0.27m thick layer of clay was compacted in all cells. A GCL or a geotextile was also used at the interface in a number of cases. A 4mm diameter hole was drilled in the flat HDPE geomembrane in all experiments. In the cases GCLs were used, the influence of the pre-hydration of the GCL at the beginning of the test was studied. When comparing situations where geotextiles and GCLs were used, results tend to show that even if GCLs incorporate a geotextile the flow rates obtained with GCLs are clearly lower that flow rates obtained in the case there is a geotextile in the interface, even when the geotextile is not fully saturated.
On a étudié au laboratoire le comportement hydraulique de 17 étanchéités composites. Celles-ci comportaient systématiquement une couche d'argile compactée, parfois renforcée par un géosynthétique bentonitique (GSB). La couche d'argile compactée était dans certains cas recouverte par un géotextile. L'étanchéité minérale était surmontée par une géomembrane en PEHD de 2mm d'épaisseur présentant un défaut circulaire de 4mm de diamètre. Dans le cas où des GSB ont été utilisés, on a étudié l'influence de la préhydratation sur le débit de fuite résultant dans l'étanchéité composite. La comparaison des cas de figures où des GSB et des géotextiles seuls ont été utilisés montre que les débits obtenus avec les GSB sont nettement inférieurs.
Origine : Fichiers produits par l'(les) auteur(s)
Loading...