Reference values for plasma concentrations of asymmetrical dimethylarginine (ADMA) and other arginine metabolites in men after validation of a chromatographic method - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Clinica Chimica Acta Année : 2007

Reference values for plasma concentrations of asymmetrical dimethylarginine (ADMA) and other arginine metabolites in men after validation of a chromatographic method

Résumé

BACKGROUND: Owing to the growing number of reports in the literature on ADMA as a possibly useful marker of endothelial health, its use in the clinical laboratory is of increasing interest. Age dependency and the small, but statistically significant differences between healthy subjects and disease groups are difficult to interpret. Additionally, levels of ADMA in comparable patient groups of different studies vary widely, even when similar methods have been used. METHODS: After analytical evaluation of a chromatographic method according to international guidelines, we analysed asymmetrical (ADMA) and symmetrical dimethyl arginine (SDMA), homo-arginine and arginine in EDTA plasma of 292 healthy males aged 20 to 75 years (y) who had passed strict inclusion/exclusion criteria. For statistical analysis, 4 age groups were formed. Group differences were identified with the non-parametric Kruskal-Wallis test. RESULTS: Calibration curves were linear throughout the selected ranges; the standard deviation for the regression line, recovery, imprecision, and accuracy results were all highly satisfactory. The reference ranges of ADMA for the 4 age groups are presented as age (mean+/-SD of age group, y); number of subjects; median, 2.5th-97.5th percentile: group <35 y: 26.7+/-4.0 y; n=78; 0.58, 0.43-0.69 micromol/L; group 35-49 y: 41.6+/-4.0 y; n=93; 0.59, 0.45-0.73 micromol/L; group 50-65 y: 57.5+/-4.2 y; n=82; 0.61, 0.46-0.78 micromol/L; and group >65 y: 69.6+/-3.3 y; n=39; 0.64, 0.54-0.79 micromol/L. CONCLUSIONS: Only highly precise methods are able to detect small differences between groups. The application of an evaluated method to a well defined group of healthy subjects should provide a basis for comparison of ADMA concentrations in different patient populations of future studies.

Dates et versions

hal-02660154 , version 1 (30-05-2020)

Identifiants

Citer

Andreas Meinitzer, Markus Puchinger, Brigitte Winklhofer-Roob, Edmond Rock, Josep Ribalta, et al.. Reference values for plasma concentrations of asymmetrical dimethylarginine (ADMA) and other arginine metabolites in men after validation of a chromatographic method. Clinica Chimica Acta, 2007, 384 (1-2), pp.141-148. ⟨10.1016/j.cca.2007.07.006⟩. ⟨hal-02660154⟩

Collections

INRA INRAE
9 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More