Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Circulation Année : 2020

Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis

Editorial, see p 269

Résumé

Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. Methods:Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. Results:A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10-599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P=0.005), cardiovascular death (relative risk, 0.82; corrected P=0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P<0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P<0.0001). Conclusions: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.

Dates et versions

hal-03144132 , version 1 (17-02-2021)

Identifiants

Citer

Christophe Saint Etienne, Leslie Grammatico-Guillon, Pierre Deharo, Arnaud Bisson, Julien Herbert, et al.. Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis. Circulation, 2020, 141 (4), pp.260-268. ⟨10.1161/CIRCULATIONAHA.119.043971⟩. ⟨hal-03144132⟩
21 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More