Diagnostic accuracy of serum (1,3)-beta-d-glucan for neonatal invasive candidiasis: systematic review and meta-analysis - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement
Article Dans Une Revue Clinical Microbiology and Infection Année : 2019

Diagnostic accuracy of serum (1,3)-beta-d-glucan for neonatal invasive candidiasis: systematic review and meta-analysis

Résumé

OBJECTIVES: Neonatal invasive candidiasis (NIC) is a leading cause of infection-related morbidity and mortality in preterm neonates. Several studies have shown that (1,3)-Beta-d-glucan (BDG) was accurate in detecting invasive fungal infection in adults, but studies in neonates are scarce. The aim was to obtain summary estimates of the accuracy of BDG detection in serum for the diagnosis of NIC. METHODS: We searched Medline, Embase, Clinicaltrials.gov, and Google Scholar (inception to July 2019). We checked the reference lists of included studies, clinical guidelines, and review articles. We included studies that assessed the accuracy of BDG against a reference standard that defined groups of patients with ordinal levels of NIC probability (e.g. proven, probable, possible) and included fungal blood culture. Participants were neonates suspected of having NIC. The intervention was BDG measurement in serum (Fungitell® assay). We assessed risk of bias and applicability using QUADAS-2. We used bivariate meta-analysis to produce summary estimates of diagnostic accuracy at prespecified positivity thresholds of 80 and 120 pg/mL. This study was registered with PROSPERO (CRD42018089545). RESULTS: We included eight studies (465 participants). Of these, two were judged at low overall risk of bias. There was substantial variability across studies in the reference standards used. At a positivity threshold of 80 pg/mL, summary estimates of sensitivity and specificity of BDG were 89% (95% CI: 80-94%) and 60% (53-66%), respectively; summary sensitivity for detecting proven cases of NIC was 99% (93-100%). At a positivity threshold of 120 pg/mL, summary estimates of sensitivity and specificity were 81% (71-88%) and 80% (67-88%), respectively. CONCLUSIONS: Because of high sensitivity, BDG seems promising to rule-out NIC. It might be too early to recommend its use because of the scarcity of reliable clinical data, heterogeneity in case definitions, and unstable accuracy estimates.
Fichier principal
Vignette du fichier
BDG SR-MA CMI Manuscript - For AA publication CLM-19-15301.R1-1.pdf (1.26 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

inserm-02319288 , version 1 (17-10-2019)

Identifiants

Citer

Jérémie F. Cohen, Antoine Ouziel, Soraya Matczak, Josephine Brice, Rene Spijker, et al.. Diagnostic accuracy of serum (1,3)-beta-d-glucan for neonatal invasive candidiasis: systematic review and meta-analysis. Clinical Microbiology and Infection, 2019, Epub ahead of print. ⟨10.1016/j.cmi.2019.09.010⟩. ⟨inserm-02319288⟩
192 Consultations
260 Téléchargements

Altmetric

Partager

More