Assessment of activated sludge process (SODEV company, type viti300) : treatment of wastewaters from Château Philippon (Bordeaux area), january to march 1999
Evaluation du procédé boues activées SODEV type viti300 : traitement des effluents du Château Philippon à Cleyrac (33), janvier à mars 1999
Abstract
Abstract : The process VITI 300 of SODEV company , mainly made of a storage tank and of an activated sludge (running at 30°C, constant flow and with addition of bio-products) have been assessed during 9 weeks in a winery. The effluents to be treated were of an average concentration in COD of 10 g/l. At steady state plant operation (flow : 300l/d, residence time in aeration tank : 18 d) the COD removal was 96,8% with a concentration in treated water in the range of 400 - 600 mg COD/l. The process is characterized by a very weak production of sludge but very high specific energy consumption.
Le procédé VITI 300 de la société SODEV, composé d'un stockage et d'une boue activée fonctionnant à 30°C avec des bioadditifs et à débit constant a été évalué sur 9 semaines consécutives dans un chai particulier. Les effluents à traiter avaient une concentration moyenne en DCO de 10 g /l . En régime stabilisé (débit 300 l/j et temps de séjour de 18 j en bassin d'aération) l'abattement en DCO est de 96,8% avec des concentrations de sortie en DCO de 400 à 600 mg/l. Le système se caractérise par une très faible production de boue mais une dépense énergétique spécifique très élevée.