MIFlowCyt-EV: a framework for standardized reporting of extracellular vesicle flow cytometry experiments - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Journal of Extracellular Vesicles Année : 2020

MIFlowCyt-EV: a framework for standardized reporting of extracellular vesicle flow cytometry experiments

Olivier de Wever
Xiaomei Yan
  • Fonction : Auteur

Résumé

Extracellular vesicles (EVs) are small, heterogeneous and difficult to measure. Flow cytometry (FC) is a key technology for the measurement of individual particles, but its application to the analysis of EVs and other submicron particles has presented many challenges and has produced a number of controversial results, in part due to limitations of instrument detection, lack of robust methods and ambiguities in how data should be interpreted. These complications are exacerbated by the field's lack of a robust reporting framework, and many EV-FC manuscripts include incomplete descriptions of methods and results, contain artefacts stemming from an insufficient instrument sensitivity and inappropriate experimental design and lack appropriate calibration and standardization. To address these issues, a working group (WG) of EV-FC researchers from ISEV, ISAC and ISTH, worked together as an EV-FC WG and developed a consensus framework for the minimum information that should be provided regarding EV-FC. This framework incorporates the existing Minimum Information for Studies of EVs (MISEV) guidelines and Minimum Information about a FC experiment (MIFlowCyt) standard in an EV-FC-specific reporting framework (MIFlowCyt-EV) that supports reporting of critical information related to sample staining, EV detection and measurement and experimental design in manuscripts that report EV-FC data. MIFlowCyt-EV provides a structure for sharing EV-FC results, but it does not prescribe specific protocols, as there will continue to be rapid evolution of instruments and methods for the foreseeable future. MIFlowCyt-EV accommodates this evolution, while providing information needed to evaluate and compare different approaches. Because MIFlowCyt-EV will ensure consistency in the manner of reporting of EV-FC studies, over time we expect that adoption of MIFlowCyt-EV as a standard for reporting EV- FC studies will improve the ability to quantitatively compare results from different laboratories and to support the development of new instruments and assays for improved measurement of EVs.
Fichier principal
Vignette du fichier
2020_welsh_journalfoextracellularvesicles_1.pdf (3.42 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02624977 , version 1 (26-05-2020)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

Joshua A. Welsh, Edwin van Der Pol, Ger J. A. Arkesteijn, Michel Bremer, Alain Brisson, et al.. MIFlowCyt-EV: a framework for standardized reporting of extracellular vesicle flow cytometry experiments. Journal of Extracellular Vesicles, 2020, 9 (1), ⟨10.1080/20013078.2020.1713526⟩. ⟨hal-02624977⟩
96 Consultations
100 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More