Gas chromatography coupled to mass spectrometry-based metabolomic to screen for anabolic practices in cattle: identification of 5a-androst-2-en-17-one as new biomarker of 4-androstenedione misuse - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Journal of Mass Spectrometry Année : 2012

Gas chromatography coupled to mass spectrometry-based metabolomic to screen for anabolic practices in cattle: identification of 5a-androst-2-en-17-one as new biomarker of 4-androstenedione misuse

Résumé

The use of anabolic steroids as growth promoters for meat-producing animals is banned within the European Union. However, screening for the illegal use of natural steroid hormones still represents a difficult challenge because of the high interindividual and physiological variability of the endogenous concentration levels in animals. In this context, the development of untargeted profiling approaches for identifying new relevant biomarkers of exposure and/or effect has been emerging for a couple of years. The present study deals with an untargeted metabolomics approach on the basis of GC-MS aiming to reveal potential biomarkers signing a fraudulent administration of 4-androstenedione (AED), an anabolic androgenic steroid chosen as template. After a sample preparation based on microextraction by packed sorbent, urinary profiles of the free and deglucurono-conjugates urinary metabolites were acquired by GC-MS in the full-scan acquisition mode. Data processing and chemometric procedures highlighted 125 ions, allowing discrimination between samples collected before and after an administration of 4-AED. After a first evaluation of the signal robustness using additional and independent non-compliant samples, 17 steroid-like metabolites were pointed out as relevant candidate biomarkers. All these metabolites were then monitored using a targeted GC-MS/MS method for an additional assessment of their capacity to be used as biomarkers. Finally, two steroids, namely 5a-androstane-3 beta,17a-diol and 5a-androst-2-en-17-one, were concluded to be compatible with such a definition and which could be finally usable for screening purpose of AED abuse in cattle. Copyright (C) 2012 John Wiley & Sons, Ltd.

Dates et versions

hal-02649448 , version 1 (29-05-2020)

Identifiants

Citer

Sebastien Anizan, Emmanuelle Bichon, Thibault Duval, Fabrice Monteau, Nora Cesbron, et al.. Gas chromatography coupled to mass spectrometry-based metabolomic to screen for anabolic practices in cattle: identification of 5a-androst-2-en-17-one as new biomarker of 4-androstenedione misuse. Journal of Mass Spectrometry, 2012, 47 (1), pp.131 - 140. ⟨10.1002/jms.2035⟩. ⟨hal-02649448⟩
7 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More