Accéder directement au contenu Accéder directement à la navigation
Article dans une revue

Analysis of GEDI Elevation Data Accuracy for Inland Waterbodies Altimetry

Abstract : The Global Ecosystem Dynamics Investigation (GEDI) Light Detection And Ranging (LiDAR) altimetry mission was recently launched to the International Space Station with a capability of providing billions of high-quality measurements of vertical structures globally. This study assesses the accuracy of the GEDI LiDAR altimetry estimation of lake water levels. The difference between GEDI’s elevation estimates to in-situ hydrological gauge water levels was determined for eight natural lakes in Switzerland. The elevation accuracy of GEDI was assessed as a function of each lake, acquisition date, and the laser used for acquisition (beam). The GEDI elevation estimates exhibit an overall good agreement with in-situ water levels with a mean elevation bias of 0.61 cm and a standard deviation (std) of 22.3 cm and could be lowered to 8.5 cm when accounting for instrumental and environmental factors. Over the eight studied lakes, the bias between GEDI elevations and in-situ data ranged from −13.8 cm to +9.8 cm with a standard deviation of the mean difference ranging from 14.5 to 31.6 cm. Results also show that the acquisition date affects the precision of the GEDI elevation estimates. GEDI data acquired in the mornings or late at night had lower bias in comparison to acquisitions during daytime or over weekends. Even though GEDI is equipped with three identical laser units, a systematic bias was found based on the laser units used in the acquisitions. Considering the eight studied lakes, the beams with the highest elevation differences compared to in-situ data were beams 1 and 6 (standard deviations of −10.2 and +18.1 cm, respectively). In contrast, the beams with the smallest mean elevation difference to in-situ data were beams 5 and 7 (−1.7 and −2.5 cm, respectively). The remaining beams (2, 3, 4, and 8) showed a mean difference between −7.4 and +4.4 cm. The standard deviation of the mean difference, however, was similar across all beams and ranged from 17.2 and 22.9 cm. This study highlights the importance of GEDI data for estimating water levels in lakes with good accuracy and has potentials in advancing our understanding of the hydrological significance of lakes especially in data scarce regions of the world.
Liste complète des métadonnées

https://hal.inrae.fr/hal-02919169
Déposant : Nicolas Baghdadi <>
Soumis le : vendredi 21 août 2020 - 17:16:02
Dernière modification le : mercredi 16 septembre 2020 - 17:21:59

Licence


Distributed under a Creative Commons Paternité 4.0 International License

Lien texte intégral

Identifiants

Citation

Ibrahim Fayad, Nicolas Baghdadi, Jean-Stéphane Bailly, Frédéric Frappart, Mehrez Zribi. Analysis of GEDI Elevation Data Accuracy for Inland Waterbodies Altimetry. Remote Sensing, MDPI, 2020, 12 (2714), ⟨10.3390/rs12172714⟩. ⟨hal-02919169⟩

Partager

Métriques

Consultations de la notice

66