Skip to Main content Skip to Navigation
Journal articles

Simplified pulse wave velocity measurement in children: Is the pOpmètre valid?

Abstract : In population exposed to cardiovascular risk, aortic stiffness is an important marker which is assessed by carotid-to-femoral pulse wave velocity (PWV). In childhood, the validated applanation tonometer SphygmoCor® can be used to measure PWV, but is limited in routine practice by the child's cooperation and operator's experience. An alternative device, the pOpmètre® is validated in adults and rapidly measures finger-to-toe PWV using 2 oxymeter-like sensors. The aim of this study is to validate the pOpmètre® device in children aged between 4 and 8 years. We compared simultaneous PWV measurements of the two devices, SphygmoCor® and pOpmètre®, in a training group, using the Bland-Altman method. Then we proposed an algorithm to correct pOpmètre® PWV (PWVpop). Finally, we validated this new algorithm in a validation group of children using the Bland-Altman method. This prospective study enrolled 26 children in the training group. Mean PWVpop was 3.919 ± 0.587 m/s and mean SphygmoCor® PWV was 4.280 ± 0.383 m/s, with a difference of-0.362(CI95%(-0.546;-0.178)) m/s. A new algorithm was defined using transit time (TTpop): corrected PWVpop (m/s) = 0.150/TTpop(s) + 1.381*Height(m) + 1.148. We enrolled 24 children in the validation group. Mean corrected PWVpop was 4.231 ± 0.189 m/ s and mean SphygmoCor® PWV was 4.208 ± 0.296 m/s with a corrected difference of 0.023(CI95%(-0.086;0.131)) m/s. With this algorithm correction, we found an agreement between PWV measured by the SphygmoCor® and the pOpmètre®, with a difference of less than 10%. Using this algorithm, the pOpmètre® could be used in clinical or research practice in young children exposed to cardiovascular risk. (This study was registered as NCT02991703).
Document type :
Journal articles
Complete list of metadata

https://hal.inrae.fr/hal-03271334
Contributor : Thomas Moyon Connect in order to contact the contributor
Submitted on : Friday, June 25, 2021 - 3:57:42 PM
Last modification on : Monday, September 27, 2021 - 5:56:08 PM

File

pone.0230817 rozé exemple pou...
Files produced by the author(s)

Identifiers

Collections

Citation

Saïd Bichali, Alexandra Bruel, Marion Boivin, Gwénaëlle Roussey, Bénédicte Romefort, et al.. Simplified pulse wave velocity measurement in children: Is the pOpmètre valid?. PLoS ONE, Public Library of Science, 2020, 15 (3), pp.1-12. ⟨10.1371/journal.pone.0230817⟩. ⟨hal-03271334⟩

Share

Metrics

Record views

10

Files downloads

23