Simplified pulse wave velocity measurement in children: Is the pOpmètre valid? - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue PLoS ONE Année : 2020

Simplified pulse wave velocity measurement in children: Is the pOpmètre valid?

Résumé

In population exposed to cardiovascular risk, aortic stiffness is an important marker which is assessed by carotid-to-femoral pulse wave velocity (PWV). In childhood, the validated applanation tonometer SphygmoCor® can be used to measure PWV, but is limited in routine practice by the child's cooperation and operator's experience. An alternative device, the pOpmètre® is validated in adults and rapidly measures finger-to-toe PWV using 2 oxymeter-like sensors. The aim of this study is to validate the pOpmètre® device in children aged between 4 and 8 years. We compared simultaneous PWV measurements of the two devices, SphygmoCor® and pOpmètre®, in a training group, using the Bland-Altman method. Then we proposed an algorithm to correct pOpmètre® PWV (PWVpop). Finally, we validated this new algorithm in a validation group of children using the Bland-Altman method. This prospective study enrolled 26 children in the training group. Mean PWVpop was 3.919 ± 0.587 m/s and mean SphygmoCor® PWV was 4.280 ± 0.383 m/s, with a difference of-0.362(CI95%(-0.546;-0.178)) m/s. A new algorithm was defined using transit time (TTpop): corrected PWVpop (m/s) = 0.150/TTpop(s) + 1.381*Height(m) + 1.148. We enrolled 24 children in the validation group. Mean corrected PWVpop was 4.231 ± 0.189 m/ s and mean SphygmoCor® PWV was 4.208 ± 0.296 m/s with a corrected difference of 0.023(CI95%(-0.086;0.131)) m/s. With this algorithm correction, we found an agreement between PWV measured by the SphygmoCor® and the pOpmètre®, with a difference of less than 10%. Using this algorithm, the pOpmètre® could be used in clinical or research practice in young children exposed to cardiovascular risk. (This study was registered as NCT02991703).
Fichier principal
Vignette du fichier
pone.0230817 rozé exemple pour formation 25062021.pdf (1.14 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03271334 , version 1 (25-06-2021)

Licence

Licence Ouverte - etalab

Identifiants

Citer

Saïd Bichali, Alexandra Bruel, Marion Boivin, Gwénaëlle Roussey, Bénédicte Romefort, et al.. Simplified pulse wave velocity measurement in children: Is the pOpmètre valid?. PLoS ONE, 2020, 15 (3), pp.1-12. ⟨10.1371/journal.pone.0230817⟩. ⟨hal-03271334⟩
9 Consultations
37 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More