Non-invasive detection of a femoral-to-radial arterial pressure gradient in intensive care patients with vasoactive agents - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Journal of Intensive Care Année : 2021

Non-invasive detection of a femoral-to-radial arterial pressure gradient in intensive care patients with vasoactive agents

Résumé

Abstract Background In patient requiring vasopressors, the radial artery pressure may underestimate the true central aortic pressure leading to unnecessary interventions. When using a femoral and a radial arterial line, this femoral-to-radial arterial pressure gradient (FR-APG) can be detected. Our main objective was to assess the accuracy of non-invasive blood pressure (NIBP) measures; specifically, measuring the gradient between the NIBP obtained at the brachial artery and the radial artery pressure and calculating the non-invasive brachial-to-radial arterial pressure gradient (NIBR-APG) to detect an FR-APG. The secondary objective was to assess the prevalence of the FR-APG in a targeted sample of critically ill patients. Methods Adult patients in an intensive care unit requiring vasopressors and instrumented with a femoral and a radial artery line were selected. We recorded invasive radial and femoral arterial pressure, and brachial NIBP. Measurements were repeated each hour for 2 h. A significant FR-APG (our reference standard) was defined by either a mean arterial pressure (MAP) difference of more than 10 mmHg or a systolic arterial pressure (SAP) difference of more than 25 mmHg. The diagnostic accuracy of the NIBR-APG (our index test) to detect a significant FR-APG was estimated and the prevalence of an FR-APG was measured and correlated with the NIBR-APG. Results Eighty-one patients aged 68 [IQR 58–75] years and an SAPS2 score of 35 (SD 7) were included from which 228 measurements were obtained. A significant FR-APG occurred in 15 patients with a prevalence of 18.5% [95%CI 10.8–28.7%]. Diabetes was significantly associated with a significant FR-APG. The use of a 11 mmHg difference in MAP between the NIBP at the brachial artery and the MAP of the radial artery led to a specificity of 92% [67; 100], a sensitivity of 100% [95%CI 83; 100] and an AUC ROC of 0.93 [95%CI 0.81–0.99] to detect a significant FR-APG. SAP and MAP FR-APG correlated with SAP ( r 2 = 0.36; p < 0.001) and MAP ( r 2 = 0.34; p < 0.001) NIBR-APG. Conclusion NIBR-APG assessment can be used to detect a significant FR-APG which occur in one in every five critically ill patients requiring vasoactive agents.
Fichier principal
Vignette du fichier
2021_Jacquet_J_Intensive_Care.pdf (1.33 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03534371 , version 1 (19-01-2022)

Licence

Identifiants

Citer

Matthias Jacquet-Lagrèze, David Claveau, Julie Cousineau, Kun Peng Liu, Jean-Gilles Guimond, et al.. Non-invasive detection of a femoral-to-radial arterial pressure gradient in intensive care patients with vasoactive agents. Journal of Intensive Care, 2021, 9 (1), pp.71. ⟨10.1186/s40560-021-00585-1⟩. ⟨hal-03534371⟩
6 Consultations
77 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More