Impact of forced aeration on vertical flow treatment wetland performances for combined sewer overflow - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Ecological Engineering Année : 2024

Impact of forced aeration on vertical flow treatment wetland performances for combined sewer overflow

Résumé

Combined Sewer Overflow Treatment Wetlands (CSO wetlands) are designed to remove pollutants under stochastic events with variable hydraulic loads. Upgrading them with forced aeration promises to increase the effectiveness and resilience of the treatment. We have tested two vertical CSO wetlands with forced aeration (CSOa and CSOb) to understand the effects of aeration on CSO treatment. Both filter beds have 0.95 and 0.80 m of saturated layer. CSOa uses gravel as top filtering layer, while CSOb utilizes sand and an additional transition layer. Tracer tests were conducted in both filters with and without aeration to assess the impact of aeration on hydraulic performance. CSOa operated with four different aeration conditions, with the optimal condition tested on both filters for comparison. Samples were taken for analysis of global parameters and the redox potential was monitored online. In the tracer test, CSOa allowed to observe the mixing impact of aeration, which avoids any preferential path when influent entered the filter. The addition of a sand layer at the surface (CSOb) allows for a more even distribution of water on the top, which limits preferential flows when aeration is off. In both filters, the results showed that aeration increased the residence time and mixing degree (NTIS <3). Testing different aeration strategies revealed the dependence of dissolved pollutant removal on oxygen supply. In CSOa, the median outlet concentration varied from 23 to 6.4 mg.L 1 in TSS, 153 to 32 mg.L 1 total COD (CODt), 124 to 20 mg.L 1 soluble COD (CODs) and 5 to 2.5 mg.L 1 NH4-N according to aeration strategy. The lower outlet concentrations were always under the highest aeration condition. Under the optimal condition (75 min on/15 min off), median removal of CSOa was 97% TSS, 85% CODt, 78% CODs and 75% NH4-N. Besides COD and TSS, outlet concentration and removal efficiency did not significantly differ between CSOa and CSOb. Pollutant removal demonstrated a linear correlation with organic surface load. Overall, forced aeration in CSO-TW distinctly affected filter dynamics and improved its performance.
Fichier principal
Vignette du fichier
Portela et al. - 2024 - Impact of forced aeration on vertical flow treatme.pdf (4.23 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte
Licence

Dates et versions

hal-04673965 , version 1 (20-08-2024)

Licence

Identifiants

Citer

Daniella Portela, Katharina Tondera, Stéphane Troesch, Pascal Molle. Impact of forced aeration on vertical flow treatment wetland performances for combined sewer overflow. Ecological Engineering, 2024, 208, pp.107359. ⟨10.1016/j.ecoleng.2024.107359⟩. ⟨hal-04673965⟩